Upgrading StorMagic VSA Firmware via vCenter Plugin

StorMagic
07/30/2026
0 (0%)
Share
  • Comments
  • Download
  • Transcript
Report Like Favorite
  • Share/Embed
  • Email
Link
Embed

Transcript


systems engineer with the technical services team. In today's video, we'll be discussing one of the multiple methods of upgrading a Stormagic SV-SAN virtual storage appliance, or VSA for short. Stormagic appliances run a standard Linux kernel as our own immutable Stormagic OS file system. These exist in a dual boot configuration to enable easy upgrade via small image file to potentially push over poor lossy WAN connectivity. Image files are supplied with a checksum to ensure the image is correct ahead of application. Configuration is then stored in a separate partition and backed up automatically to partner nodes for a restore mechanism. The overarching concept is a simple throwaway appliance that does a job and can be easily rebuilt if even needed. It is possible to push a new version, but not apply, or push a version and automatically restart to apply the new version. Stormagic's VSAs can have their firmware upgraded via the Stormagic vCenter plugin. This offers smart updating of the VSA firmware and staggered rebooting of the VSAs. By health checking the systems during the workflow, this ensures that the shared storage remains available. This means that this can be done during production hours. If we take a look at the vCenter that we already have deployed, under administration and client plugins, we can see we have a Stormagic plugin installed. But before we utilize this, we will need to download the image file from support.stormagic.com. You will need to be logged in in order to access the downloads page, but once logged in, click downloads. And under SV-SAN, we will click on VSA and witness appliance firmware. We'll agree to the license agreement, and we will click the download link here. This will download a zip file. I've already downloaded the file and I've extracted the image file here. Once we have that, we can go back to our vCenter into our inventory. We'll click on the VCSA layer of the vCenter, click configure, and under Stormagic plugin, click dashboard and upgrade. From here, we are in the firmware section, and this is where we can upload our new image. We'll click upload image here. We will go to our file explorer. We will grab the image, drag and drop on here to upload it. Once this is successful, we can close this window and we can see our new image file is here. We can now click upgrade VSAs. This will bring a wizard up that we will now run through. Hit next. We're specifically looking to upgrade site three cluster. We can specify which VSA we want to upgrade specifically, but we want to upgrade both of these. So we're going to select both of them. We will also need to give the cluster an upgrade name just for scheduling. Hit next. We can select between the different firmware images that we've uploaded. We're going to select the latest version, which is 6.7. We'll click next. From here, we can schedule an upgrade if we want to schedule it for a certain time of the day. I don't need to, I'm going to do this right now, but you can if you want. We'll click next and we'll click finish. And from here, we can check our scheduled tasks. We can see the test upgrade is ready to go. Once we do that, we can log into our VSAs and we can watch as they get upgraded. As we can see, this VSA is getting rebooted now. As we can see, VSA 1 on site 3 is now in version 6.7, as we can see in the top right corner of the console. If I refresh the webpage, log back into it, we can see it is in 6.7 If I check the other VSA, VSA 2, we should see this now reboot after VSA 1 is rebooted. And there it goes. And again, we can see now the VSA 2 is rebooted and is now in version as you can see in the top right corner of this console here. That concludes the dashboard upgrade. If you have any further questions, you can contact support at support at stormagic.com. Thank you for watching.

TL;DR

  • StorMagic VSAs use a dual-boot Linux architecture with immutable OS and separate configuration partitions, enabling simple firmware upgrades via small image files suitable for WAN deployment
  • The vCenter plugin provides smart upgrade orchestration with health checking and staggered node rebooting, maintaining storage availability throughout the process
  • Firmware images are downloaded from the support portal, uploaded through the plugin interface, and can be applied immediately or scheduled for specific maintenance windows
  • The upgrade workflow automatically coordinates node reboots and verifies cluster health, allowing production-hour upgrades without storage service interruption

VSA Architecture and Upgrade Approach

StorMagic's Virtual Storage Appliances (VSAs) run on a dual-boot Linux kernel with an immutable OS file system, designed specifically for easy upgrades over limited bandwidth connections. The architecture separates configuration data into a dedicated partition that automatically backs up to partner nodes, enabling simple restoration if needed. This throwaway appliance design allows administrators to push new firmware versions without applying them immediately, or to push and automatically restart for instant deployment. The system uses checksummed image files to verify integrity before application, ensuring reliable upgrades even across poor WAN links.

vCenter Plugin Upgrade Workflow

The demonstration walks through upgrading VSA firmware using StorMagic's vCenter plugin, which provides intelligent health checking and staggered node rebooting to maintain storage availability during the upgrade process. After downloading the firmware image from the support portal and uploading it through the plugin interface, administrators can select specific VSAs for upgrade, schedule the operation for off-hours if desired, and monitor progress through the vCenter task scheduler. The plugin automatically coordinates the upgrade sequence, rebooting VSA nodes one at a time while verifying cluster health, allowing the entire process to occur during production hours without storage downtime.

Chapters

0:00 - Introduction and VSA Architecture
1:11 - vCenter Plugin Overview
1:42 - Downloading Firmware Image
2:10 - Uploading Image via Plugin
2:58 - Configuring Upgrade Wizard
4:06 - Monitoring Upgrade Progress

Key Quotes

0:29 "Stormagic appliances run a standard Linux kernel as our own immutable Stormagic OS file system. These exist in a dual boot configuration to enable easy upgrade via small image file to potentially push over poor lossy WAN connectivity."
0:52 "The overarching concept is a simple throwaway appliance that does a job and can be easily rebuilt if even needed."
1:16 "This offers smart updating of the VSA firmware and staggered rebooting of the VSAs. By health checking the systems during the workflow, this ensures that the shared storage remains available."
1:26 "This means that this can be done during production hours."

FAQ

Can StorMagic VSA firmware upgrades be performed during production hours without downtime?

Yes, the vCenter plugin upgrade method includes smart health checking and staggered node rebooting that ensures shared storage remains available throughout the upgrade process, allowing upgrades during production hours.

What happens to VSA configuration data during a firmware upgrade?

Configuration data is stored in a separate partition and automatically backed up to partner nodes, providing a restore mechanism. The immutable OS design means the firmware upgrade doesn't affect stored configuration.


Categories:
  • » Webinar Library » StorMagic
  • » Data Protection » Backup & Recovery
  • » Data Protection
Channels:
News:
Events:
Tags:
  • Data Protection
  • How-To
  • Technical Deep Dive
  • Getting Started
  • Virtual Storage Appliance Management
  • Firmware Upgrade Procedures
  • vCenter Integration
  • High Availability Storage
  • Edge Infrastructure Management
  • Linux-based Storage Systems
  • WAN-optimized Deployment
Show more Show less

Browse videos

  • Related
  • Featured
  • By date
  • Most viewed
  • Top rated
  •  

              Video's comments: Upgrading StorMagic VSA Firmware via vCenter Plugin

              Industry Events (Sponsor Hosted)

              • Aug
                03

                Discover DLP Memories: The ever-evolving triage agent enhancing efficiency each shift.

                08/03/202611:00 AM ET
                • Aug
                  06

                  Safeguarding Sensitive Data in the Era of Public AI Platforms

                  08/06/202604:00 AM ET
                  • Aug
                    06

                    Same Tactics, Enhanced Speed: AI Agents’ Impact on Identity Attacks

                    08/06/202602:00 PM ET
                    More events

                    Upcoming Webinar Calendar

                    • 08/03/2026
                      11:00 AM
                      08/03/2026
                      Discover DLP Memories: The ever-evolving triage agent enhancing efficiency each shift.
                      https://www.truthinit.com/index.php/channel/2062/discover-dlp-memories-the-ever-evolving-triage-agent-enhancing-efficiency-each-shift/
                    • 08/06/2026
                      04:00 AM
                      08/06/2026
                      Safeguarding Sensitive Data in the Era of Public AI Platforms
                      https://www.truthinit.com/index.php/channel/2058/safeguarding-sensitive-data-in-the-era-of-public-ai-platforms/
                    • 08/06/2026
                      02:00 PM
                      08/06/2026
                      Same Tactics, Enhanced Speed: AI Agents’ Impact on Identity Attacks
                      https://www.truthinit.com/index.php/channel/2064/same-tactics-enhanced-speed-ai-agents-impact-on-identity-attacks/
                    • 08/07/2026
                      11:30 AM
                      08/07/2026
                      Refreshing Beverage Ideas Paired with Essential Cybersecurity Insights
                      https://www.truthinit.com/index.php/channel/2063/refreshing-beverage-ideas-paired-with-essential-cybersecurity-insights/
                    • 08/13/2026
                      12:00 PM
                      08/13/2026
                      Harnessing AI for Secure Innovation in the Enterprise with Netskope & Omada
                      https://www.truthinit.com/index.php/channel/2065/harnessing-ai-for-secure-innovation-in-the-enterprise-with-netskope-omada/
                    • 08/19/2026
                      12:00 PM
                      08/19/2026
                      Becoming Agent Ready: Insights and Strategies with Cyera
                      https://www.truthinit.com/index.php/channel/2036/becoming-agent-ready-insights-and-strategies-with-cyera/
                    • 09/02/2026
                      12:00 PM
                      09/02/2026
                      Unified Data Security in Action: Uncover, Analyze, and Resolve Threats
                      https://www.truthinit.com/index.php/channel/2045/unified-data-security-in-action-uncover-analyze-and-resolve-threats/
                    • 09/30/2026
                      04:00 AM
                      09/30/2026
                      AI Command Center: Optimizing Visibility and Control in Your Operations
                      https://www.truthinit.com/index.php/channel/2024/ai-command-center-optimizing-visibility-and-control-in-your-operations/
                    Truth in IT
                    • Sponsor
                    • About Us
                    • Terms of Service
                    • Privacy Policy
                    • Contact Us
                    • Preference Management
                    Desktop version
                    Standard version